Project Portfolio - Chelmsford Bus Station
Project: |
Chelmsford Bus Station – 53 Central Park |
| Place of Project: |
Chelmsford |
| Client: |
Barratt Eastern Counties |
| Kind of Window / Facade: |
The requirement to achieve a state of the art U-Value of 1.2 for common apartments in an aluminium facade construction BRAND UK designed a high spec curtain wall using 0.5 Ug LowE glass units; Triple glazing designed with 2 chambers provides an fantastic value of 0.5 Ug. |
| System of Provider: |
Schüco FW50+.HI (The system description HI stands for "High Insulation"); FW 50+.HI are further development of the FW50+ façade system – a system that can only meet the high requirements of energy saving regulations; Polythermide isolators with integral foam profiles on both sides; Different external pressure plates of aluminium and feature caps from 15mm to 100mm; External screws are grade A4 quality stainless steel. |
| Architect |
DLA Architectural |
| Builder: |
Ardmore Construction |
Accordingly to our calculations we can confirm the following results of each induvidual curtain wall screen in the building:
Window: |
Current U-Value: |
Elevation: |
| WT23 a&b |
1.07 |
Duke St / Viaduct RD |
| WT18a next WT 23b |
1.11 |
Duke St |
| WT18a |
1.41 |
Duke St |
| WT18 |
1.42 |
Duke St / Viaduct RD |
| WT22 a&b |
1.03 |
Duke St |
| WT21 |
0.97 |
Duke St |
| WT13 |
1.40 |
Fairfield RD |
| WT25 |
1.27 |
Fairfield RD |
| WT26 |
1.22 |
Fairfield RD |
| WT14 |
1.39 |
Fairfield RD |
| WT19 |
1.31 |
Fairfield RD |
| WT15 a&b |
1.04 |
Fairfield RD / Backyard |
| WT16 |
1.34 |
Backyard |
| WT27 |
1.33 |
Backyard |
| WT20 |
1.43 |
Backyard |
| WT17 a&b |
1.03 |
Viaduct RD / Backyard |
| WT24 |
1.49 |
Viaduct RD |
Download Brochure in PDF format


|